627 research outputs found

    A Brief Introduction to the New Architecture of SIETTE

    Full text link

    Late coronary occlusion after intracoronary brachytherapy

    Get PDF
    BACKGROUND: Intracoronary brachytherapy appears to be a promising technology to prevent restenosis. Presently, limited data are available regarding the late safety of this therapeutic modality. The aim of the study was to determine the incidence of late (>1 month) thrombosis after PTCA and radiotherapy. METHODS AND RESULTS: From April 1997 to March 1999, we successfully treated 108 patients with PTCA followed by intracoronary beta-radiation. Ninety-one patients have completed at least 2 months of clinical follow-up. Of these patients, 6.6% (6 patients) presented with sudden thrombotic events confirmed by angiography 2 to 15 months after intervention (2 balloon angioplasty and 4 stent). Some factors (overlapping stents, unhealed dissection) may have triggered the thrombosis process, but the timing of the event is extremely unusual. Therefore, the effect of radiation on delaying the healing process and maintaining a thrombogenic coronary surface is proposed as the most plausible mechanism to explain such late events. CONCLUSIONS: Late and sudden thrombosis after PTCA followed by intracoronary radiotherapy is a new phenomenon in interventional cardiology

    Geographic Miss

    Get PDF
    Background—A recognized limitation of endovascular ß-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary ß-radiation. Methods and Results—We analyzed 50 consecutive patients treated with ß-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84±0.6 versus 0.15±0.4 and 0.09±0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). Conclusions—These data support the hypothesis that the combination of injury and low-dose ß-radiation induces deleterious outcome

    Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy

    Get PDF
    BACKGROUND: A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. METHODS AND RESULTS: We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). CONCLUSIONS: These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome

    Radioactive stents delay but do not prevent in-stent neointimal hyperplasia

    Get PDF
    BACKGROUND: Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and volumetric ECG-gated 3D intravascular ultrasound (IVUS). METHODS AND RESULTS: Of 40 patients undergoing initial stent implantation, 26 were event-free after the 6-month follow-up period and 22 underwent repeat catheterization and IVUS at 1 year; they comprised half of the study population. Significant luminal deterioration was observed within the stents between 6 months and 1 year, as evidenced by a decrease in the angiographic minimum lumen diameter (-0.43+/-0.56 mm; P:=0.028) and in the mean lumen diameter in the stent (-0.55+/-0. 63 mm; P:=0.001); a significant increase in in-stent neointimal hyperplasia by IVUS (18.16+/-12.59 mm(3) at 6 months to 27.75+/-11. 99 mm(3) at 1 year; P:=0.001) was also observed. Target vessel revascularization was performed in 5 patients (23%). No patient experienced late occlusion, myocardial infarction, or death. By 1 year, 21 of the initial 40 patients (65%) remained event-free. CONCLUSIONS: Neointimal proliferation is delayed rather than prevented by radioactive stent implantation. Clinical outcome 1 year after the implantation of stents with an initial activity of 6 to 12 microCi is not favorable when compared with conventional stenting

    Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation

    Get PDF
    BACKGROUND: Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. METHODS AND RESULTS: We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm(3)) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm(3)) compared with low-activity radioactive stent implantation (NIH 21.2 mm(3)) and conventional stent implantation (NIH 20.8 mm(3)) (P:=0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling. CONCLUSIONS: Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting

    Three dimensional intravascular ultrasonic assessment of the local mechanism of restenosis after balloon angioplasty

    Get PDF
    OBJECTIVE: To assess the mechanism of restenosis after balloon angioplasty. DESIGN: Prospective study. PATIENTS: 13 patients treated with balloon angioplasty. INTERVENTIONS: 111 coronary subsegments (2 mm each) were analysed after balloon angioplasty and at a six month follow up using three dimensional intravascular ultrasound (IVUS). MAIN OUTCOME MEASURES: Qualitative and quantitative IVUS analysis. Total vessel (external elastic membrane), plaque, and lumen volume were measured in each 2 mm subsegment. Delta values were calculated (follow up - postprocedure). Remodelling was defined as any (positive or negative) change in total vessel volume. RESULTS: Positive remodelling was observed in 52 subsegments while negative remodelling occurred in 44. Remodelling, plaque type, and dissection were heterogeneously distributed along the coronary segments. Plaque composition was not associated with changes in IVUS indices, whereas dissected subsegments had a greater increase in total vessel volume than those without dissection (1.7 mm(3) v -0.33 mm(3), p = 0.04). Change in total vessel volume was correlated with changes in lumen (p < 0.05, r = 0.56) and plaque volumes (p < 0.05, r = 0.64). The site with maximum lumen loss was not the same site as the minimum lumen area at follow up in the majority (n = 10) of the vessels. In the multivariate model, residual plaque burden had an influence on negative remodelling (p = 0.001, 95% confidence interval (CI) -0.391 to -0.108), whereas dissection had an effect on total vessel increase (p = 0.002, 95% CI 1.168 to 4.969). CONCLUSIONS: The mechanism of lumen renarrowing after balloon angioplasty appears to be determined by unfavourable remodelling. However, different patterns of remodelling may occur in individual injured coronary segments, which highlights the complexity and influence of local factors in the restenotic process

    Preserved endothelium-dependent vasodilation in coronary segments previously treated with balloon angioplasty and intracoronary irradiation

    Get PDF
    BACKGROUND: Abnormal endothelium-dependent coronary vasomotion has been reported after balloon angioplasty (BA), as well as after intracoronary radiation. However, the long-term effect on coronary vasomotion is not known. The aim of this study was to evaluate the long-term vasomotion of coronary segments treated with BA and brachytherapy. METHODS AND RESULTS: Patients with single de novo lesions treated either with BA followed by intracoronary beta-irradiation (according to the Beta Energy Restenosis Trial-1.5) or with BA alone were eligible. Of these groups, those patients in stable condition who returned for 6-month angiographic follow-up formed the study population (n=19, irradiated group and n=11, control group). Endothelium-dependent coronary vasomotion was assessed by selective infusion of serial doses of acetylcholine (ACh) proximally to the treated area. Mean luminal diameter was calculated by quantitative coronary angiography both in the treated area and in distal segments. Endothelial dysfunction was defined as a vasoconstriction after the maximal dose of ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated normal endothelial function. In contrast, 10 distal nonirradiated segments (53%) and 5 control segments (45%) demonstrated endothelium-dependent vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage of change in mean luminal diameter after ACh was significantly higher in irradiated segments (P=0.01). CONCLUSIONS: Endothelium-dependent vasomotion of coronary segments treated with BA followed by beta-radiation is restored in the majority of stabl

    Outcome from balloon induced coronary artery dissection after intracoronary beta radiation

    Get PDF
    OBJECTIVE: To evaluate the healing of balloon induced coronary artery dissection in individuals who have received beta radiation treatment and to propose a new intravascular ultrasound (IVUS) dissection score to facilitate the comparison of dissection through time. DESIGN: Retrospective study. SETTING: Tertiary referral centre. PATIENTS: 31 patients with stable angina pectoris, enrolled in the beta energy restenosis trial (BERT-1.5), were included. After excluding those who underwent stent implantation, the evaluable population was 22 patients. INTERVENTIONS: Balloon angioplasty and intracoronary radiation followed by quantitative coronary angiography (QCA) and IVUS. Repeat QCA and IVUS were performed at six month follow up. MAIN OUTCOME MEASURES: QCA and IVUS evidence of healing of dissection. Dissection classification for angiography was by the National Heart Lung Blood Institute scale. IVUS proven dissection was defined as partial or complete. The following IVUS defined characteristics of dissection were described in the affected coronary segments: length, depth, arc circumference, presence of flap, and dissection score. Dissection was defined as healed when all features of dissection had resolved. The calculated dose of radiation received by the dissected area in those with healed versus non-healed dissection was also compared. RESULTS: Angiography (type A = 5, B = 7, C = 4) and IVUS proven (partial = 12, complete = 4) dissections were seen in 16 patients following intervention. At six month follow up, six and eight unhealed dissections were seen by angiography (A = 2, B = 4) and IVUS (partial = 7, complete = 1), respectively. The mean IVUS dissection score was 5.2 (range 3-8) following the procedure, and 4.6 (range 3-7) at follow up. No correlation was found between the dose prescribed in the treated area and the presence of unhealed disse
    corecore